Category: Support

multimeter

What’s the problem if you connect the power but not working?

Need to use a multimeter to check if the power lacks of the phase.

Read More
How to reset the inverter

How to reset the inverter when you receive the new one?

Step 1: Press PRG, show P0, press UP, till show PP, press ENTER show PP.00, press UP show PP.01, press ENTER, show 0 or 0000, press UP, last 0 change into 1, press ENTER, show PP.02 or PP.00. This purpose of…

Read More
Inverter

How to check if the inverter is broken?

2. If it still shows, then need to check the inverter. Remove off U, V, W wires from the inverter, press PRG, show P0, enter, show P0.00, change into P0.01, enter, show 0, change into 2, enter, press PRG and start…

Read More
2023111509344660

How to change the language of the compressor on MAM6070?

Enter into 用户参数-Press 2 times of Down-press last second line “中文” then it will change into English.

Read More
2023111509232671

How to change the language of the compressor on MAM890 PLC?

Home page-press down-enter into 用户参数-press down and find 语言选择

Read More
2023111509161333

How to choose the wire and the breaker for the air compressor?

For 3 phases compressor: 7.5kw compressor uses 4 square meters of wires, the breaker/air switch uses 32A. 11kw compressor uses 6 square meters of wires, the circuit breaker uses 56A. 15kw compressor uses 8 square meters of wires, the circuit breaker…

Read More
2023111508543422

How to adjust the MAM890 plc after the maintenance?

2. Adjust set data as below.OIL FILTER SET: 2000HO-A FILTER SET: 2000HAIR FILTER SET: 2000H LUBE SET: 2000HGREASE RESET: 2000HBELT RESET: 0000H

Read More